R-2001D Basic Model
R.2001D/HS With high stability oscillator
R.2002D With IEEE-488 option
R.2002D/HS High stability oscillator and IEEE-466 Bua option
R-2004D With Motorola DES option
R-2004D/HS High stability oscillator and Motorola DES option
R-2005D With Motorola SECURENET option
R.2005D/HS High stability oscillator and Motorola SECURENET
option
R.2008D With cellular option
R.2008D/HS High stability oscillator and cellular option
R-2009D With IEEE-488 Bus and cellular options
R.2009D/HS With high stability oscillator, IEEE-488 Bus and cellular
option
R.2010D With UK cellular option
R.2010D/HS High stability oscillator and UK cellular option
R.2011D With IEEE-488 Bus and UK cellular option
R.2011D/HS High stability oscillator, IEEE-488 Bus, and UK cellular
option
R-2021 D With Motorola Trunked Radio option
R-2021D/HS High stability oscillator and Motorola Trunked Radio
option
R-2045D With Motorola DES and SECURENET options
R-2045D/HS High stability oscillator and Motorola's DES
and SECURENET options
NOTE: Factory set 220 Volt models are also available. Add "/220"
to model number.
R-2001D Options/numbers
Moderator: Queue Moderator
Re: R-2001D Accessories
Optional Accessories
RTP-1002A Battery Pack
RTL-4056B Protective Canvas Cover
RTL-4065A Transit Case
RTL-4075A RF Detector Probe
RTA-4000A Telescoping Antenna
RTP-1002A Battery Pack
RTL-4056B Protective Canvas Cover
RTL-4065A Transit Case
RTL-4075A RF Detector Probe
RTA-4000A Telescoping Antenna
Re: R-2001D Options/numbers
- 0 Master Reset
10 Encode/Decode
11 Encode/Decode
12 Encode/Decode
13 Encode/Decode
20 Monitor
21 Monitor
22 Monitor
23 Monitor
24 Monitor
25 Monitor
26 Monitor
30 Frequency
31 Frequency
32 Frequency
33XY Frequency
3300 Frequency
34XY Frequency
3400 Frequency
Clears all special functions
(default state)
Clears all IX E/D special
functions (default state)
Baseband
Decode only
Encode Only
Clears all 2X monitor
special functions (default
state)
Enables 300 Hz LPFL
Enables 3 KHz LPFL
Enables 20 KHz LPFL
Enables 5 Hz HPFL
Enables 300 Hz HPFL
Enables 3 KHz HPFL
Clears all frequency 3X
special functions (default
state)
Enables direct frequency
readout (10 Hz resolution)
Enables direct frequency
readout (1 Hz resolution)
Enables scan lock from
XOO MHz to YOO MHz
Enables full-band
scan lock
Enables scan latch from
XOO MHz to YOO MHz
Enables full-band scan
latch
CODE MODE ACTIVATES
Enables automatic
DVM ranging (default
state)
40
41
42
43
44
50
51
52
60
61
62
63
64
65
70
71
72
73
DVM
DVM
DVM
DVM
DVM
Enables 1.0 V DVM range
Enables 10 V DVM range
Enables 100V DVM range
Enables 300V DVM range
Modulation Meter Enables automatic
modulation ranging
(default state)
Modulation Meter Enables 10 KHz range
Modulation Meter Enables 100 KHz range
Auto counter resolution
(default state)
Counter
Counter
Counter
Counter
Counter
Counter
System Control
System Control
System Control
System Control
0.1 Hz resolution
1 Hz resolution
10 Hz resolution
100 Hz resolution
1 KHz resolution
Sets factory control states
(default state)
Sets the current state
as the power-on state
Initiates a system self test
Disables the automatic
switching to monitor mode
if the input signal is over
0.1.W.
74 Mutes speaker during GEN
77XY
7700
78XYZ
78000
79
99
System Control
System Control
System Control
System Control
System Control
System Control
Sets the last XY in RF
memory presets as duplex
Resets from duplex to
simplex (default state)
Sets deviation audible
alarm to XY.Z KHz
Disables audible alarm
(default state)
Resets nonvolatile memory
Software Version Shows P/N of resident
software version
Email me if interested, and I will send that way.
Re: R-2001D Options/numbers
Thanks Earnest, That makes sense with what I have. I know about all the special functions too.
Dave
2005D
Dave
2005D
Re: R-2001D Options/numbers
R.2024D/HS With high stability oscillator, IEEE-488 Bus, SECURENET options DES, DES-XL, DVP, DVP-XL